| Plate Classification | CTCP Plate |
|---|---|
| Resolution | 2-99% @200 Lpi |
| Exposure Energy | 50-70 Mj/square Centimeter |
| Length Of Run (Unbaked) | 80,000 To 100,000 Impressions |
| Length Of Run (Baked) | Over 100,000 Impressions |
| Plate Type | UV CTP Plate |
|---|---|
| Resolution | 2-99% @200 Lpi |
| Exposure Energy | 50-70 Mj/square Centimeter |
| Length Of Run | Over 100,000 Impressions |
| Developing Time | 25-30 Sec |
| Resolution | 2-99% At 200 Lpi |
|---|---|
| Exposure Energy | 50-70 Mj/square Centimeter |
| Substrate | Electro Chemically Grained & Anodized Lithograph Aluminum |
| Gauge (mm) | 0.15, 0.20, 0.25, 0.30, 0.40 |
| Length Of Run (Unbaked) | Unbaked: 80,000 To 100,000 Impressions |
| Plate Type | CTCP Plate |
|---|---|
| Exposure Energy | 50-70 Mj/square Centimeter |
| Resolution | 2-99% @200 Lpi |
| Length Of Run | Baked: Over 100,000 Impressions |
| Substrate | Electro Chemically Grained & Anodized Lithograph Aluminum |
| Plate Type | CTCP Plate |
|---|---|
| Resolution | 1-99% @200 Lpi & 20 Ufm |
| Spectral Sensitivity | 400-430nm - UV Laser |
| Shelf Life | 12 Months Under Recommended Storage Conditions |
| Run-length | 1,000,000 Impressions |
| Plate Classification | CTCP Plate |
|---|---|
| Exposure Energy | 50-65 Uj/square Centimeter |
| Safelight | Handle Under Yellow Safelight (UV Free) |
| Resolution | 1-99% @200 Lpi & 20 Ufm |
| Developing Time | 20 ± 3 Sec |
| Plate Classification | UV CTP Plate |
|---|---|
| Resolution | 1-99% @200 Lpi & 20 Ufm |
| Run-length | 1,000,000 Impressions Baked |
| Exposure Energy | 50-65 Uj/square Centimeter |
| Coating Color | Light Blue |
| Plate Classification | CTCP Printing Plate |
|---|---|
| Exposure Energy | 50-65uj/square Centimeter |
| Resolution | 1-99% @200 Lpi & 20 Ufm |
| Gauge | 0.15, 0.20, 0.25, 0.30, 0.40mm |
| Run-length | 1,000,000 Impressions Baked |
| Plate Type | Violet Plate |
|---|---|
| Run Length | 100,000 Impressions Unbaked. Actual Run Length May Vary According To Press/paper/ink Conditions. |
| Exposure Energy | 70-90uj/cm2 (based On Platesetter And Developing Condition) |
| Resolution | 2%-98% @150lpi (depending On Capability Of Imaging Device) |
| Substrate | Electrochemically Grained And Anodized Aluminum |
| Spectral Sensitivity | 400-410nm |
|---|---|
| Run Length | 100, 000 Impressions |
| Recommended Screen Method | 1-99 @200 Lpi Am / 20u FM And Mixture |
| Processing | Without Processing, Directly On Press |
| Shelf Life | 12 Months Under Recommended |